Showing results: 31 - 45 of 86 items found.
-
CPCI-AD8-opt8 -
ALPHI Technology Corporation
The CPCI-AD8/16 module provides a 3U high performance data acquisition subsystem. There are (8) eight or (16) sixteen 100/200 KSPS ADC’s for maximum performance. The Local DSP can be used to simply move data samples to the CPCI bus or can provide processing functions such as limit checking, FFT’s, digital filtering, etc. Software can be downloaded to the DSP via the CPCI interface.
-
CPCI-AD16 -
ALPHI Technology Corporation
The CPCI-AD16 module provides a 3U high performance data acquisition subsystem. The Local DSP can be used to simply move data samples to the CPCI bus or can provide processing functions such as limit checking, FFT’s, digitalfiltering, etc. Application software can be downloaded to the DSP via the CPCI interface. Instrumentation amplifiers provide over-voltage protection, gain and filtering on a per channel basis. Internal scan and trigger clocks are derived from either the CPCI bus clock or the local DSP clock. Dual 32 bit timers can programmed to pace the acquisition process. The CPCI-AD16 can also accept external scan and trigger signals from a front panel connector.
-
DAQ -
Keysight Technologies
Installation and configuration is fast and easy with standard connectors, soft front panels and Keysight connection expert. In addition, software drivers support the most common programming environments such as Visual Studio®, C, C++, Visual Basic, MATLAB® and LabVIEW™.
-
U2353A -
Keysight Technologies
The U2353A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2353A to simulate simultaneous analog input acquisition.
-
U2352A -
Keysight Technologies
The U2352A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2352A to simulate simultaneous analog input acquisition.
-
DAQe-2500 Series -
ADLINK Technology Inc.
ADLINK DAQe-2500 series are high-speed and high-performance analog output multi-function DAQ PCI EXpress cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQe-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory.
-
40-201-004 -
Pickering Interfaces Ltd.
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-201-008 -
Pickering Interfaces Ltd.
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-190B-402 -
Pickering Interfaces Ltd.
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
40-190B-302 -
Pickering Interfaces Ltd.
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-502 -
Pickering Interfaces Ltd.
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
50-190-201 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-190-001 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-190-101 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-200-008 -
Pickering Interfaces Ltd.
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.